Vape particle size depends on which diameter the instrument reports
Read aerodynamic and electrical mobility diameters as different size definitions before comparing aerosol distributions.
No Vape · Updated

Read how the size was obtained
Start with the horizontal axis and the methods paragraph. A size in nanometers can come from classifying particles by different physical responses. Note whether the report used inertial impaction, electrical mobility, imaging or another principle. A familiar length unit does not specify what property the diameter represents.
Separately read the vertical axis. A plot can weight its distribution by particle number or mass. That choice is independent of which diameter appears along the bottom. Match both before treating peaks in two figures as answers to the same question.
Identify the physical equivalence named by the method
An aerosol methods paper explains aerodynamic diameter using a reference sphere of unit density that matches the particle’s settling response. Its description of electrical mobility uses a reference sphere with matching motion in an electric field at the stated charge. Real particles need not be those reference spheres. Each diameter is a way to describe a particular measured behavior.
The definitions can differ for the same aerosol. Converting two length units does not remove assumptions about size, shape, density or the measurement model. If authors convert a distribution between definitions, find the particular assumptions they used and keep those qualifications with the result.
Use a real experiment to keep instrument choices visible
Mikheev and colleagues compared electrical mobility and inertial impaction measurements for e-cigarette aerosol in one laboratory study. Their methods discuss differences in instrument range, resolution and sample handling. This is a reason to retain each measurement principle in a comparison without treating one instrument as universally correct or using the paper’s results to rank devices.
Imagine two fictional charts for an inert teaching aerosol. Both put their main feature near the same number on a nanometer axis, but one labels mobility diameter and the other labels aerodynamic diameter. The matching number does not establish matching particle geometry. Check the definitions and any documented mapping before comparing them.
Summarize both size axes without a health inference
Write the reported diameter definition, instrument range, distribution weighting and known sampling conditions. If a chart does not identify one of those details, leave the comparison conditional. Missing sizes outside an instrument’s scope cannot be filled by making the axis labels match.
An aerosol size comparison does not give a personal absorbed amount, identify individual health effects or make a laboratory setting appropriate for use. A useful reading conclusion can stay technical and brief: these figures use different size definitions, and the report provides or does not provide a justified mapping.
Sources and scope
Sources inform the guidance. The worksheets and examples are No Vape editorial suggestions, not tested treatments.
- Aerosol Science and Technology, Mikheev et al. — Aerosol size distribution measurement of electronic cigarette emissions using combined differential mobility and inertial impaction methods
- Journal of Aerosol Science, Kittelson et al. — Particle emissions from mobile sources: Discussion of ultrafine particle emissions and definition, section 2.2
- No Vape — No Vape — app features and store links
Written with AI assistance and checked against the cited sources. No clinical review is claimed. This guide covers practical planning, not individual medical treatment. How we research and write