Skip to content
No Vape

Most particles by number can carry a minority of the measured mass

Read number-weighted and mass-weighted aerosol plots as different summaries, using a neutral worked example rather than a product ranking.

No Vape · Updated

Open book on a cafe table
Illustrative image · Lucille Emi Oh / Unsplash

Ask what receives the weight in this plot

The word most is incomplete unless the summary tells you most by what measure. A graph can describe numbers of particles within size intervals, or mass within those intervals. The same aerosol can produce different-looking summaries because those weights answer different questions. This is not an inconsistency that must be resolved by choosing the prettier curve.

Copy the horizontal size definition, vertical quantity and reported size range before comparing panels. A percentage can be a share of counted particles or a share of estimated mass. Dropping that label can turn a correct figure into an incorrect claim even when every displayed number was copied accurately.

Find how the published mass curve was obtained

The original study Electronic cigarette power affects count concentration and particle size distribution of vaping aerosol presents separate count and mass plots. Its methods explain a calculated mass distribution using particle counts, spherical-particle and density assumptions. That supports a specific reading distinction, not a universal conversion for every vape.

Keep measured and calculated quantities labeled. A calculation can be informative while depending on assumptions and the instrument’s captured size range. Do not treat a mass curve derived from counts as an independent weighing experiment or assume a different report used the same particle model.

PLOS ONE — original research, available in PMC: Electronic cigarette power affects count concentration and particle size distribution of vaping aerosol

Use a fictional distribution you can check

Imagine ten ideal spheres of the same material: nine have diameter one arbitrary unit and one has diameter three. The smaller spheres are nine out of ten objects, so they represent 90 percent of the count. For these ideal spheres, volume scales with the cube of diameter; the larger sphere therefore has 27 times one small sphere’s volume.

With equal density, assign each small sphere one arbitrary mass unit and the large sphere 27. Total mass is 36 units, of which the large sphere holds 27, or 75 percent. Thus smaller objects dominate the number while the single larger object dominates mass. These are invented geometry values, not vaping measurements, exposure estimates or a device experiment.

Return to the actual legend with a bounded sentence

For a real report, write which distribution supports the statement: most counted particles fell within the reported smaller-size region, or most calculated mass fell within another region. Preserve the study’s qualifiers. If the methods do not establish the required weighting or size boundary, leave that interpretation unresolved rather than borrowing assumptions from the fictional example.

Check whether two panels concern the same tested sample and procedure. A change in distribution cannot automatically be attributed to one device feature when collection, dilution or instrument conditions also differ. This reading task requires no additional vaping, equipment adjustment or home collection.

Keep the summary separate from personal health conclusions

Neither the larger share of counts nor the larger share of mass alone ranks health effects, identifies chemical contents or calculates what a person absorbed. A small-looking peak is not a safety certificate, and a dramatic peak is not an individual diagnosis. Those conclusions require other evidence and appropriate expertise.

The useful output is an accurately labeled comparison, with calculated quantities and unknowns retained. You can use it to question a headline that says most particles without its weighting, while keeping practical quitting decisions independent of laboratory arithmetic. This original worked example is an aid to reading a figure, not clinical review.

Sources and scope

Sources inform the guidance. The worksheets and examples are No Vape editorial suggestions, not tested treatments.

  1. PLOS ONE — original research, available in PMC — Electronic cigarette power affects count concentration and particle size distribution of vaping aerosol
  2. No Vape — No Vape — app features and store links

Written with AI assistance and checked against the cited sources. No clinical review is claimed. This guide covers practical planning, not individual medical treatment. How we research and write