A laboratory spike-recovery result checks the method in the sample material
Read a matrix-spike quality-control statement without confusing added test material, an unaltered sample and a product ingredient claim.
No Vape · Updated

Identify the control before interpreting its number
A report may place ordinary sample results beside several quality-control results. Find the label, what material was tested and what was deliberately added for the control. Do not combine those rows into a list of substances originally found in the product. If the control’s relationship to the sample is unclear, ask for the laboratory explanation.
EPA’s analytical quality-control guidance distinguishes a matrix spike, used to assess the method in the particular sample material, from a laboratory control sample in a cleaner reference matrix. It explains their different questions about matrix effects and laboratory performance. This environmental-method guidance supplies terminology here; it is not a vape testing requirement or health standard.
US Environmental Protection Agency: Quality Assurance (QA) - Quality Control (QC) · US Environmental Protection Agency: ERLN Laboratory Requirements Document, Version1.6 (August2011), Glossary: Matrix Spike
Keep the recovery statement in its own column
Use a reading note with spaces for the native sample result, control type, target addition and the report’s recovery explanation. Leave details absent from the report unresolved. You do not need to calculate a recovery correction or recreate the method to distinguish these objects. In particular, do not subtract a control percentage from a product claim.
Imagine a fictional report has a native-sample row and a separate matrix-spike recovery row for marker Q. A summary calls the latter the percentage of Q in the vape. The correction is to identify it as a method-performance check involving an addition. No actual chemical amount, product result or acceptable recovery range is supplied by this example.
Read the laboratory’s qualification instead of supplying one
Look for whether the report says the check met its applicable criteria and whether it qualifies affected sample results. A flagged recovery does not identify its cause by itself. Keep the actual laboratory explanation, including an unresolved explanation, rather than declaring either contamination or dishonesty from the label alone.
EPA discusses using control results together to examine sample-matrix effects and laboratory performance. That does not authorize a reader to adopt the environmental program’s criteria for a vaping sample or to repair a result with home arithmetic. The laboratory and relevant technical expertise must address whether the actual method and control apply to the material and question.
US Environmental Protection Agency: Quality Assurance (QA) - Quality Control (QC)
Separate analytical quality from the later health claim
A well-described quality check does not establish that every constituent was measured or that the tested material represents every product sold. Those are separate coverage questions. It also cannot show what a particular person inhaled or absorbed. Do not use a recovery figure to choose a device or set an allowed number of puffs.
Finish with a modest description: the report includes this control to examine this aspect of the method, and gives this interpretation or leaves this question open. The original reading note is not a laboratory protocol or a professional appraisal. It preserves the difference between a test of measurement performance and a claim about product composition or personal health.